rosemount 3051tg manual

rosemount 3051tg manual

Rosemount 3051TG Manual Overview

The Rosemount 3051TG pressure transmitter manual provides comprehensive details for gauge and absolute pressure measurement. This includes various model ranges, such as the 3051TG/TA, and the coplanar 3051C. It covers essential information for users regarding specifications and physical characteristics.

Rosemount 3051TG/TA Model Ranges

The Rosemount 3051TG and 3051TA pressure transmitters offer several model ranges to accommodate various application requirements. Specifically, the Rosemount 3051TG/TA models include Range 1, which measures up to 750 psi (51.7 bar), and Range 2, which extends to 1500 psi (103.4 bar). Additionally, certain models, such as the 3051H, can measure up to 3626 psig (25 MPa). These ranges ensure accurate measurements across diverse industrial processes. The 3051CD/CG series also provides varying ranges, including Range 0 at 750 psi (51.7 bar), Range 1 at 2000 psig (137.9 bar) , and Ranges 2-5 which can reach 3626 psig (250 bar) or 4500 psig (310.3 bar) depending on the options selected. These diverse options provide users with a transmitter that will meet their specific pressure measurement requirements. These models are designed to integrate sensor and electronic technologies to provide reliable measurements.

Operating Temperature Limits for Electronics

The Rosemount 3051 series, including the 3051TG and 3051TA models, has specific operating temperature limits for its electronics to ensure accurate and reliable performance. The electronics of these transmitters are designed to function within a temperature range of -40 to 185 degrees Fahrenheit (-40 to 85 degrees Celsius). It is crucial to adhere to these limits to prevent damage or inaccurate readings from the device. Exceeding these temperature ranges can compromise the integrity of the internal components, potentially leading to performance degradation or complete failure. Therefore, users must consider the ambient operating environment when deploying these transmitters. Proper installation and suitable environmental controls are essential to maintain the device’s electronic components within the specified temperature range, thus ensuring the longevity and accuracy of the pressure measurements.

Rosemount 3051C Coplanar Pressure Transmitters

The Rosemount 3051C Coplanar Pressure Transmitters are recognized as the industry standard for differential, gauge, and absolute pressure measurements. These transmitters offer a versatile solution with various styles, materials, and configurations to accommodate a wide range of applications. The coplanar design of the 3051C allows for direct mounting and easy installation, enhancing their adaptability in different process environments. These transmitters are known for their robust construction, ensuring reliable performance in demanding conditions. The 3051C series provides accurate and stable measurements, making them a preferred choice in various industrial settings. Their industry-standard design ensures seamless integration into existing systems, while their wide range of options caters to specific requirements. The coplanar design contributes to the ease of use and installation, making them a dependable option.

Rosemount 3051TG Specifications

This section details the performance specifications of the Rosemount 3051TG, including range limits and conformance standards. Key aspects cover lower range limits, and adherence to specified performance within defined tolerances, as well as material selection.

Performance Specifications

The Rosemount 3051TG pressure transmitter boasts impressive performance specifications, designed for accurate and reliable measurements in diverse applications. This includes specific ranges such as Range 1 with a 750 psi (51.7 bar) capacity and Range 2 extending to 1500 psi (103.4 bar). These specifications are essential for selecting the right transmitter for a particular task. The 3051TG is engineered for high accuracy and stability, ensuring consistent performance over extended periods. Notably, the long term stability is a key feature, contributing to the transmitter’s reliability. Furthermore, the performance specifications encompass details on response time, ensuring that the device accurately captures rapid changes in pressure. These parameters are crucial for maintaining process efficiency and safety. The transmitters also meet stringent industry standards for performance and safety, providing users with the confidence in their measurements. The product data sheets provide detailed information on these aspects, with specific values for various ranges and configurations, ensuring transparency and informed decision-making during selection and implementation.

Rosemount 3051TG Lower Range Limit

The Rosemount 3051TG lower range limit is a critical factor in determining the suitability of the transmitter for specific applications. This limit indicates the minimum pressure the device can accurately measure, and it varies depending on atmospheric conditions. Understanding this lower range limit is essential for ensuring precise and reliable pressure readings, particularly in low-pressure environments. The lower range limit is not a fixed value and may fluctuate, necessitating careful consideration during installation. It is essential to consult the product data sheets and specifications for the accurate lower range limit for the specific 3051TG model, as this information is vital for accurate measurements and avoiding errors. These limits are crucial in achieving precise process control and maintaining accurate records. Therefore, the lower range limit is a primary factor to consider when selecting a transmitter model for a specific application. The Rosemount manual also emphasizes the importance of verifying the suitability of the lower range limit to ensure optimal transmitter performance.

Conformance to Specification

The Rosemount 3051TG series is engineered to adhere to strict performance specifications, ensuring reliable and accurate measurements. Conformance to specification is typically measured using a 3σ (sigma) standard, which highlights the device’s ability to consistently perform within the stated parameters. This high standard of conformance means that the transmitters offer dependable data for critical industrial processes. The 3σ conformance is a testament to the advanced technology and quality control measures employed in the manufacturing of the Rosemount 3051TG. This ensures that the transmitter consistently provides accurate and reliable measurements. Users can have confidence that the device will perform as expected across a wide range of operating conditions. Furthermore, conformance to specification is essential for maintaining process efficiency and minimizing potential errors in measurement and control. This commitment to quality is a core element of the Rosemount 3051TG design, guaranteeing that it meets the demanding requirements of various industrial applications. This also includes specific measurement tolerances.

Rosemount 3051TG Physical and Material Details

The Rosemount 3051TG incorporates robust physical specifications and material selections. It uses 316 stainless steel for wetted parts, enhancing durability. This ensures reliable performance across diverse industrial applications, including demanding process environments.

Physical Specifications and Material Selection

The Rosemount 3051TG pressure transmitter is designed with careful consideration of physical specifications and material selection to ensure reliable performance in various industrial settings. The transmitter’s construction primarily employs 316 stainless steel for wetted parts, offering excellent corrosion resistance and durability. This material choice makes it suitable for a wide range of process applications, including those with harsh or corrosive substances. The robust design is further enhanced by its ability to withstand demanding operating conditions. The physical dimensions and mounting configurations are meticulously engineered to facilitate easy installation and integration into existing systems. The selection of materials also includes consideration for compatibility with different process media and temperature ranges. The pressure transmitter’s housing is designed to protect the internal components from external environmental factors, such as moisture and dust, ensuring long-term reliability. This focus on material integrity and precise physical design contributes to the overall robustness and long operational life of the Rosemount 3051TG.

Rosemount 3051TG Additional Features

The Rosemount 3051TG offers absolute and gauge pressure measurements, long-term stability, HART compatibility for easy configuration, and various communication protocols. These features enhance the transmitter’s versatility and performance in diverse industrial applications.

Absolute and Gauge Pressure Measurements

The Rosemount 3051TG pressure transmitter is engineered to deliver precise measurements for both absolute and gauge pressure applications, catering to diverse industrial needs. Absolute pressure measurements, crucial for applications where a vacuum reference is required, are facilitated by the 3051TA model. Conversely, the 3051TG model focuses on gauge pressure measurements, which are referenced against atmospheric pressure. This dual capability allows the transmitter to be utilized in a wide range of processes, from simple tank level monitoring to complex control loops. The available measurement ranges span from 0.3 to 10,000 psi, ensuring that the transmitter can accommodate various pressure levels. The quick response time of the 3051TG ensures that pressure changes are accurately detected and relayed, which is important for process control. These measurements are further enhanced by the transmitter’s robust design, which allows it to handle harsh environments. The integration of sensor, electronic technology, and a single isolation diaphragm design further adds to the reliability and accuracy of these measurements.

Long Term Stability

The Rosemount 3051 series, particularly the 3051TG model, is renowned for its exceptional long-term stability, ensuring consistent and reliable performance over extended periods. Specifically, the 3051C models within the series offer a long-term stability of 0.125% of URL for 5 years, for ranges 2-5. This stability is maintained even under fluctuating conditions, such as temperature changes of up to 50°F (28°C) and line pressure variations of up to 1000 psi (6.9 MPa). This remarkable stability minimizes the need for frequent recalibration, reducing downtime and maintenance costs. The design of the 3051TG incorporates advanced sensor technology and robust materials, which contribute to its enduring performance. This ensures that the transmitter provides consistent accuracy throughout its operational life, which is very important for maintaining process efficiency and safety. The long-term stability of the Rosemount 3051 series is a key factor in its widespread adoption across various industries. It is a testament to its durable design and advanced engineering.

HART Compatibility and Configuration

The Rosemount 3051TG pressure transmitter is designed with full HART compatibility, allowing for seamless integration into existing process control systems. This HART compatibility simplifies configuration and calibration processes, enabling users to easily adjust parameters and monitor performance. The transmitter supports the 4-20 mA HART protocol, a widely used standard in industrial automation. This ensures that the device can communicate with a broad range of control systems and devices. Configuration can be done via hand-held communicators, or dedicated software tools, making it user-friendly for technicians. The HART protocol also enables advanced diagnostics, allowing for proactive maintenance and minimizing downtime. Furthermore, the Rosemount 3051TG’s HART compatibility allows for remote configuration and monitoring, improving operational efficiency and reducing the need for manual intervention. This makes the Rosemount 3051TG a versatile and adaptable solution for various industrial applications. It provides both basic measurement and advanced communication capabilities.

Communication Protocols

The Rosemount 3051TG pressure transmitter offers a variety of communication protocols to suit different system requirements. Beyond the standard 4-20 mA HART protocol, it supports other advanced protocols such as WirelessHART, FOUNDATION fieldbus, and Profibus. WirelessHART enables flexible installation and reduces wiring costs, especially in hard-to-reach areas. FOUNDATION fieldbus allows for more complex data communication and advanced diagnostics, supporting a fully digital plant environment. Profibus is another widely used industrial protocol, providing robust and reliable data transfer. These diverse communication options enable the Rosemount 3051TG to integrate seamlessly with various control systems and automation architectures. The selection of the appropriate protocol depends on the specific application and the existing infrastructure. The transmitter’s ability to support these protocols enhances its versatility and makes it a suitable choice for a wide range of industrial processes. These options ensure seamless integration into modern automation systems.

Leave a Reply